Difference between revisions of "Summary - B2"
m (5 revisions imported) |
|||
| (2 intermediate revisions by the same user not shown) | |||
| Line 2: | Line 2: | ||
<p><strong>EN 14152:2003 Food stuffs – Determination of vitamin B2 by HPLC:</strong> | <p><strong>EN 14152:2003 Food stuffs – Determination of vitamin B2 by HPLC:</strong> | ||
<br class="atl-forced-newline" /></p> | <br class="atl-forced-newline" /></p> | ||
| − | |||
<p><strong>Scope</strong> | <p><strong>Scope</strong> | ||
<br class="atl-forced-newline" /></p> | <br class="atl-forced-newline" /></p> | ||
| − | |||
<p>This European Standard specifies a method for the determination of vitamin B2 in foodstuffs by high performance liquid chromatography (HPLC). The determination of vitamin B2 content is carried out by measurement of riboflavin. | <p>This European Standard specifies a method for the determination of vitamin B2 in foodstuffs by high performance liquid chromatography (HPLC). The determination of vitamin B2 content is carried out by measurement of riboflavin. | ||
<br class="atl-forced-newline" /></p> | <br class="atl-forced-newline" /></p> | ||
| − | |||
<p><strong>Principle</strong> | <p><strong>Principle</strong> | ||
<br class="atl-forced-newline" /></p> | <br class="atl-forced-newline" /></p> | ||
| − | |||
<p>Riboflavin in an appropriate sample solution is determined after acid hydrolysis followed by dephosphorylation using an enzymatic treatment by highs performance liquid chromatographic (HPLC) separation with a fluorometric detection. | <p>Riboflavin in an appropriate sample solution is determined after acid hydrolysis followed by dephosphorylation using an enzymatic treatment by highs performance liquid chromatographic (HPLC) separation with a fluorometric detection. | ||
<br class="atl-forced-newline" /></p> | <br class="atl-forced-newline" /></p> | ||
| − | |||
<p><strong>Precision data</strong> | <p><strong>Precision data</strong> | ||
Latest revision as of 13:33, 9 May 2019
EN 14152:2003 Food stuffs – Determination of vitamin B2 by HPLC:
Scope
This European Standard specifies a method for the determination of vitamin B2 in foodstuffs by high performance liquid chromatography (HPLC). The determination of vitamin B2 content is carried out by measurement of riboflavin.
Principle
Riboflavin in an appropriate sample solution is determined after acid hydrolysis followed by dephosphorylation using an enzymatic treatment by highs performance liquid chromatographic (HPLC) separation with a fluorometric detection.
Precision data
|
|
CRM 421
|
CRM 487
|
|---|---|---|
|
Repeatability standard deviation s r, mg/100 g |
0,046 |
0,181 |
|
Repeatability coefficient of variation, % |
3,2 |
1,7 |
|
Repeatability value r = [2,83 x s r], mg/100 g |
0,130 |
0,511 |
|
Reproducibility standard deviation s R, mg/100 g |
0,106 |
0,832 |
|
Reproducibility coefficient of variation, % |
7,3 |
7,9 |
|
Reproducibility value r = [2,83 x s R], mg/100 g |
0,30 |
2,35 |
Data derived from EN 14152:2003.